8.7.6.2 Passwords
To prevent unauthorized changes in the application selection, use the Password function (S6.5.1). By default, the password is not
active.
N O T I C E
Keep the password in a safe location!
8.7.6.3 Setting a Password
Set a password to protect the application selection menu.
N O T I C E
Keep the password in a safe location! The password cannot be changed if a valid password is not available.
Procedure
In Security submenu, push the Menu button Right.
To go to the edit mode, push the Menu button Right.
The display shows 0 that blinks.
There are 2 options to set a password: with the Browser buttons or by digits. The password can be a number between 1 and
65535.
With the Browser buttons: Push the Browser buttons Up and Down to find a number.
By digits: Push the Menu button Right. A second 0 shows on the display.
Push the Browser buttons to set digit on the right.
Push the Menu button Left, and set the digit on the left.
To add a third digit, push the Menu button Left. Set up to 5 digits with Menu and Browser buttons and set the digit
for each one with the Browser buttons.
To accept the new password, push the [enter] button.
The password activates after the Timeout time (P6.6.3) (see 8.7.7.4 Setting the Timeout Time).
8.7.6.4 Entering a Password
In a password-protected submenu, the display shows Password? Use these instructions to enter the password.
Procedure
When the display shows Password?, give the password with the Browser buttons.
8.7.6.5 Deactivating the Password Function
Use these instructions to deactivate the password protection for application selection menu.
Procedure
Find the Password (S6.5.1) in the Security menu with the Browser buttons.
To go to the edit mode, push the Menu button Right.
Set value 0 for the password.
8.7.6.6 Locking a Parameter
Use the Parameter lock function to prevent changes to the parameters. If the parameter lock is active, the text locked shows on the
display when trying to edit a parameter value.
N O T I C E
This function does not prevent unauthorized changes of parameter values.
Procedure
In the Security menu (M6), find the Parameter lock (P6.5.2) with the Browser buttons.
To go to the edit mode, push the Menu button Right.
AQ351737303996en-000201 / DPD00888100 | Danfoss A/S © 2023.09
Using the Control Panel
VACON® NXP IP00 Drive Modules
Operating Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VACON NXP IP00 and is the answer not in the manual?

Danfoss VACON NXP IP00 Specifications

General IconGeneral
BrandDanfoss
ModelVACON NXP IP00
CategoryControl Unit
LanguageEnglish

Related product manuals