6159930310_07_01/2016 - 17 -
4.5 - Wireless battery tool management
• Tap this icon to create the Tightening Unit no. 51
which is dedicated to the wireless battery tool.
• Tap this icon to start the Tightening Unit setup.
• Refer to the previous chapters to set up the general
features, the run reverse and the curves parameters.
4.6 - Wireless battery tool parameters
This chapter will show how to customize the environment and
the display of the wireless battery tool.
• Tap «BT parameters»to display the sub-menus.
4.6.1 - Feature parameters
Lock tool at
disconnection
disabled The wireless battery tool
is not locked when the
communication is lost with the
controller.
enabled The wireless battery tool
can be locked when the
communication is lost with the
controller.
The lifetime value denes the maximum
time the tool is able to work without
controller communication.
Block if FIFO
is full
The wireless battery tool is able to keep
a dened number of results previously
generated (typically 10,000).
When option "Block if FIFO full" is enabled,
the wireless battery tool is locked when
FIFO level is 100%. It allows to ensure the
traceability of all generated results. The
tool is unlocked when the connection is re-
established and FIFO level is under 100%.
When disabled, no lock is set when FIFO
level is 100% and traceability of results is
not ensured.