EasyManuals Logo

Desoutter CVI3 Vision User Manual

Desoutter CVI3 Vision
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6159930310_07_01/2016- 6 -
Original instructions.
© Copyright 2015, Desoutter HP2 7SJ UK
All rights reserved. Any unauthorized use or copying of
the contents or part thereof is prohibited. This applies in
particular to trademarks, model denominations, part numbers
and drawings. Use only authorized parts. Any damage or
malfunction caused by the use of unauthorised parts is not
covered by Warranty or Product Liability.
1 - SAFETY INSTRUCTIONS
1.1 - General instructions
To reduce risk of injury, everyone using,
installing, repairing, maintaining, changing
accessories on, or working near this tool must
read and understand the safety instructions
before performing any such task.
Failure to follow all instructions listed below
may result in electric shock, re and / or serious
personal injury.
Refer to the following booklets:
- General safety instructions, part no. 6159931790
- Quick-start user manual, part no. 6159932290.
SAVE THESE INSTRUCTIONS CAREFULLY.
1.2 - Personal safety
WARNING: This power tool must be earthed.
If the power tool is not earthed, the system will
disable the power stage and the tool will not start.
The error message "Bad tool ground" will be
displayed.
1.2.1 - Differential circuit breaker
The controller has a residual current circuit breaker with
over-current protection tted with a differential circuit-breaker
for user protection. Any insulation defect in the cable or in the
tool is detected by this device.
The circuit breaker protects from a leakage current exceeding
30 mA in 50 μs by automatic power cutoff. The device
protects the operator from any electric shock and protects,
the controller from the deterioration. To make sure that the
detection of leakage current is functioning properly, the device
must be tested monthly by pushing the yellow pushbutton.
It also has a fuse function. It protects the system from any
short-circuit by automatic power cutoff.
Refer to Appendix B - JVL6-32.
The circuit breaker must be switched on to restart the
controller.
1.2.2 - Power consumption
The decision to install an external differential circuit-breaker
depends on the type of internal electric network in the
customer’s plant.
This device detects any insulation defect between one of the
phases of the network and the earth, immediately stops the
tool by automatic power cutoff and protects the operator from
any electric shock.
Should circuit-breakers be installed at line head, we
recommend that you select equipment with the following
specications:
- Single-phased 240V 16A - curve D
- Single-phased 110V 32A - curve D.
Refer to Appendix A: Controller Power
consumption: Current inlet.
For information:
- standby consumption is 17 W.
- the max power available supplied via the 24Volt power
supply (between pin 2 and 3 on I/O connector):
CVI3 Vision or CVI3 Function: 1 A (24V)
TWINCVI3: 2 A (24V).
1.2.3 - Power supply
Only use the cord supplied with the controller to connect to
the mains power supply.
Do not modify the cord or use it for any other purpose.
Only use genuine Desoutter replacement parts.
Failure to follow these instructions may result in electric
shock.
1.3 - Tool use hazards
The selection of the tool takes account of the operating
conditions as stated by the user.
When selected, they must not exceed the operating limits as
specied by the manufacturer.
Any excessive internal temperature of the tool electric motor
is detected and stops the tool. The motor can start again only
after the temperature has decreased.
Motor temperature limits are different for handheld tools and
for xed tools:
- 60°C for handheld tools.
- 100°C for xed tools.
Although our cables are designed to work under drastic
conditions, we recommend that you check the following points
for a longer service life:
- Bending radius should not be lower than 10 times the cable
diameter.
- Friction with the outer sheath should be restricted.
- Any direct pull on the cable should be avoided.
1.4 - Tool care and service
Only experienced and qualied personnel (authorized
electricians) are entitled to open and have access to the
inside of the controller.
If in doubt, return the tool to a Desoutter-authorized service
centre. Contact your Desoutter representative for support.
Disconnect from power supply and wait 10 minutes before
starting service operations.
Failure to wait 10 minutes may result in electric
shock from not yet unloaded capacitors.
According to Directive 2012/19/CE concerning
Waste Electrical and Electronic Equipment
(WEEE), this product must be recycled.
Contact your Desoutter representative or consult
the website "www.desouttertools.com" to nd
out where you can recycle this product.

Table of Contents

Other manuals for Desoutter CVI3 Vision

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Desoutter CVI3 Vision and is the answer not in the manual?

Desoutter CVI3 Vision Specifications

General IconGeneral
BrandDesoutter
ModelCVI3 Vision
CategoryController
LanguageEnglish

Related product manuals