Page 67 of 112
DMM-0200 Product User Guide
159 Swanson Road
Boxborough, MA 01719
Tel: 508-475-3400
Email: sales@dovermotion.com
Read: [variable] = DI
Conditional: IF DI=[variable]
ENDIF
IF DI=[value]
ENDIF
Examples:
IF DI=255
DO= 1 ; * * *If no digital inputs are triggered, set DO= 1
ENDIF
DI(1-8J
Description:
Read: Gets the digital input value
Performax 2EX has 8 digital inputs
Syntax:
Read: [variable] = DI[1-8]
Conditional: IF DI[1-8]=[variable]
ENDIF
IF DI[1-8]=[0 or
1] ENDIF
Examples:
IF DI1=1
DO= 1 ; * * *If digital input 1 is triggered, set DO= 1
ENDIF
DO
Description:
Read: Gets the digital output value
Write: Sets the digital output value
Performax 2EX has 8 digital outputs
Syntax:
Read: [variable] = DO
Write: DO = [value]
DO = [variable]
Conditional: IF DO=[variable]
ENDIF
IF DO=[value]
ENDIF
Examples:
DO=7 ;***Turn first 3 bits on and rest off
DO(1-8J
Description:
Read: Gets the individual digital output value
Write: Sets the individual digital output value Performax 2EX has 8 digital outputs
Syntax:
Read: [variable] = DO[1-8]
Write: DO[1-8] = [0 or 1]