168
When Messages Appear
When Messages Appear
Message Status and Solution
Status: The machine failed to read REG mark because it is not printed
correctly.
Solution: Press the STOP key, then check whether the REG mark is
printed straight and the document is not skewed.
(P.22 for REG mark speci cations)
Status: The machine failed to read REG mark because of an incorrect
REG mark position.
Solution: Press the STOP key, then check the REG mark position
and margin slitter position. If REG mark is printed out of
speci cation, print it on an appropriate position.
(P.22 for REG mark speci cations)
. Status: The machine cannot perform the JOB because of the false
data received from a computer.
Solution: Con rm the JOB contents and then press the STOP key.
Status : Gutter slits and slits are allocated to the locations that
prevent the sensor from sensing a document.
The messages appear when the following conditions of
1
and
2
are met simultaneously.
1
: (55.1 to 60 mm)
2
: (95.1 to 100 mm)
Solution : Press the STOP key to clear the error, then change the JOB
details so that the gutter slits, slits or perforations of the RTM
(rotary tool module (option)) is not overlapped with either
range of 55.1–60 mm and 95.1–100 mm.
Status :
Solution : Pressing the START key or the TEST key continues
processing the JOB. When processing is continued, the
gutter slits are not ejected to the waste box but are ejected to
the exit tray.
*
or is displayed for * in the gure on the left.
Cannot read
REG mark
to clear
JOB ERROR
Slit/RTM is at
55.1-60mm and
95.1-100mm.
Change Slit/RTM
positions.
to clear
JOB ERROR
Non-operator’s side
Operator’s side
Slit
Gutter slit
100 mm
Slit
Gutter slit
95.1 mm
60 mm
55.1 mm
1
2
Document
feed
direction
The gutter slits
are output on
the exit tray on
this job.
*Continue
1. The message appears when the slit positions that
make the gutter slits less than 5 mm that is out of the
speci cations are entered and the JOB is about to be
processed.
2. The message appears when the slitters allocations disable
the gutter de ector to drop the gutter slits and the JOB is
about to be processed.
Check REG
position
to clear
Check JOB detail
to clear
REG READ ERROR 4
JOB ERROR
REG READ ERROR 3