Set-up instructions
90 Operating manual 867 Version 01.0 - 12/2012
7.12 Electrical connection
7.12.1 Checking the mains voltage
Important: The voltage on the type plate of the sewing drive must
correspond to the mains voltage.
1. Check the mains voltage before connecting the machine.
7.12.2 Fitting and connecting the sewing lamp and
sewing lamp transformer
The sewing lamp is an additional component that is not part of the
standard delivery package.
Danger to life due to electric shock.
The machine may only be connected by trained
electrical specialists.
Disconnect the power plug before carrying out
work on the electrical equipment.
Make sure the power plug cannot be unintention-
ally reinserted.
The voltage on the type plate of the sewing drive
must correspond to the mains voltage.
DANGER
Danger to life due to electric shock.
The supply voltage for the sewing lamp remains
switched on when the sewing machine is switched
off
at the main power switch.
Pull out the power plug before fitting and connect-
ing the sewing lamp and sewing lamp transformer
Make sure the power plug cannot be unintention-
ally reinserted.
DANGER

Table of Contents

Other manuals for DURKOPP ADLER 867

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DURKOPP ADLER 867 and is the answer not in the manual?

DURKOPP ADLER 867 Specifications

General IconGeneral
Stitch TypeLockstitch
Max Stitch Length12 mm
Needle System134-35
Needle Thread TensionAdjustable
LubricationAutomatic
TypeIndustrial Sewing Machine
Max Sewing Speed3000 stitches per minute
Presser Foot Lift20 mm
Power Requirements230V/50Hz