4.6.2.3 Parameter display and parameter set for the high-speed counter:
In the parameter display of a counter relay you change the mode, the
setpoint and the enable of the parameter display.
4.6.2.4 Value range
The counter relay counts between 0 and 32000.
4.6.2.5 Behavior when value range is reached
The easy control relay is in RUN mode.
The value is retained if the counter reaches 32000. If the counter counts
down and reaches 0, this value is retained.
Parameter display in RUN mode:
4.6.2.6 Retention
The high-speed counter can be run with the retentive actual value. You can
select the retentive counter relays in the SYSTEM… → RETENTION… menu.
C5 to C7, C8 and C13 to C16 can be selected.
If a counter relay is retentive, the actual value is retained when the operating
mode changes from RUN to STOP as well as when the supply voltage is
switched off.
When easy is restarted in RUN mode, the counter relay continues with the
retentively stored actual value.
C13 Counter function relay number 13
H H high-speed counter mode (H = high speed)
+ • + appears in the PARAMETER menu.
•
- does not appear in the PARAMETER menu
S Setpoint, constant from 00000 to 32000
Current setpoint, constant (1 250)
# Contact has not switched.
â Contact has switched.
Actual value (877)