2 Installation
2.3 Ter minations
Operating instructions 05/10 MN05013003Z-EN www.eaton.com 29
2.3 Terminations
2.3.1 Tools
Slot-head screwdriver, width 3.5 mm, tightening torque 0.6 Nm.
2.3.2 Cable cross-sections
Solid: 0.2 to 4 mm
2
Flexible with ferrule: 0.2 to 2.5 mm
2
2.4 Connecting the power supply
2.4.1 Cable protection
Connect on easy a cable protection (F1) rated for at least 1 A (slow).
2.4.2 Supplying AC basic units
EASY…-AB-RC(RCX), EASY…-AC-R(RC, RCX)
Figure 7: Supply voltage to AC basic unit
The required connection data for device types,
easy-AB with 24 V AC, easy-AC with standard voltages of
100 V AC up to 240 V AC, easy-DA with 12 V DC and easy-DC
with 24 V DC are provided in the ( section “8.3 Technical
data”, page 210).
The easy500 and easy700 basic units run a system test for two
seconds after the power supply has been switched on. Either
RUN or STOP mode will be activated after these two seconds,
depending on the default setting.
When easy is switched on for the first time, its power supply
circuit behaves like a capacitor. Ensure that reed relay contacts
or proximity switches are not used as the switching device for
switching on the power supply.
NNL
N
F1
L