2 Installation
2.6 Connecting outputs
42 Operating instructions 05/10 MN05013003Z-EN www.eaton.com
2.6 Connecting outputs
The Q outputs operate inside the easy as isolated contacts.
Figure 27: Q output
The associated relay coils are controlled in the easy circuit diagram via the
following outputs:
• Q1 to Q4 and Q1 to Q8 (Q6), basic units.
• S1 to S8 (S6), expansion devices.
The signal states of the outputs can be used in the easy circuit diagram as
N/O or N/C contacts for other switching conditions.
The relay or transistor outputs are used to switch loads such as fluorescent
tubes, filament bulbs, contactors, relays or motors. Prior to installation
observe the technical limit values and data for the outputs (→ section “8.3
Technical data”, page 210).
2.6.1 Connecting relay outputs
2.6.1.1 EASY512-..-R..
Figure 28: EASY512-…-R… relay outputs
Q1 q1
Q1
12
0 V H, N
F 8 A/B 16
L1, L2, L3 (115/230 V h)
+ 24 V H
25 000
R
L
24 V H 8 A
115 V h 8 A
230 V h 8 A
3 A
3 A
3 A
1000 W
10 x 58 W
1
2
1
2
1
2
1
2
10 000 000
Q1
S1
Q2
S2
Q3
S3
Q4
S4