5 settings
5.3 Alter parameters
168 Operating instructions 05/10 MN05013003Z-EN www.eaton.com
▶ Press DEL and ALT to call up the System menu.
▶ Select LANGUAGE… to change the menu language.
The language selection for the first entry ENGLISH is displayed.
▶ Use
Í or Ú to select the new menu language, e.g. Italian (ITALIANO).
▶ Confirm with OK. ITALIANO is assigned a tick.
▶ Exit the menu with ESC.
easy will now show the new menu language.
Press ESC to return to the Status display.
5.3 Alter parameters
easy allows you to change function relay parameters such as timing relay
setpoint values and counter setpoints without having to call up the circuit
diagram. This is possible regardless of whether easy is running a program or
is in STOP mode.
▶ Press OK to switch to the main menu.
▶ Start the parameter display by selecting PARAMETER.
All function relays are displayed as a list.
The following preconditions must be fulfilled in order for a parameter set to
be displayed:
• A function relay must have been included in the circuit diagram.
• The PARAMETER menu must be available.
• The parameter set must have been enabled for access, indicated by the
+ character at the bottom right of the display.
ENGLISH Æ
DEUTSCH å
FRANCAIS
ESPANOL æ
ITALIANO
PORTUGUES
NEDERLANDS
SVENSKA
POLSKI
TURKCE
CESKY
MAGYAR
SICUREZZA
SISTEMA...
LINGUA MENU
CONFIGURA…
T3 Ü S+
T8 X M:S +
C4 N +
O3 +
Ö2+
A1 EQ +
A3 LT +
→
You can enable or disable parameter access using the “+” or “–
” parameter set characters in the circuit diagram.