All simple operations may be used with a delay to activate (Delay true) and deactivate (Delay
false). The figure below shows the original signal. Next, it is shown how the setting of the Delay
true and Delay false parameters affects this signal.
The bulb goes on following a button press and remains on for another 120 s after releasing
the button.
This functionality can be achieved by means of the Is True
operation with the parameter Delay false = 120s.
Page 109/137