Log
The Log panel contains the logging configuration.
Parameter Description
Log to USB A channel / variable determining if the device is to log to a USB.
The value one means that logging is to be active the whole time.
This parameter defines the conditions when logging is
active/inactive
Create new log every [min] Determines the maximum size of a single file in minutes. When
the size of the logged data exceeds the predefined time, a new file
will be created
Default log condition The ADU device allows you to create 4 logging profiles. These
profiles are defined in Menu/Logged channels. This allows you to
record to a file different channels with different frequencies
depending on the current condition.
The Default log condition parameter defines the default profile
that is to be used if none of the conditions for the profiles are met.
Log Cond2 channel A channel/function activating the logging of the Cond 2 profile
Log Cond3 channel A channel/function activating the logging of the Cond 3 profile
Log Cond4 channel A channel/function activating the logging of the Cond 4 profile
CAN Bus / Serial setup
The CAN Bus / Serial setup panel is used for configuring the CAN BUS and for the RS232 serial
communication.
Parameter Description
CAN 2 terminator Activation of the terminator on the CAN 2 bus.
CAN 2 speed The speed of the CAN 2 bus
GPS CAN Bus Selection of the CAN bus to which the GPS module is connected.
Tire temp. cameras
CAN Bus
Selection of the CAN bus to which the thermal imaging cameras
measuring the tire temperature are connected
Tire temp. Cameras
base ID
The base ID of the first thermal imaging camera (in the hexadecimal
notation).
Serial protocol Selection of a serial protocol:
Ecumaster serial protocol – a serial protocol supported by the the
EMU and EMU Black computers
Page 128/137