WARNING!
Engine control CAN bus driver speed must be at least 1Mbps. This is due to the
fact that the ADU CAN1 bus supports only this communication speed.
IMPORTANT!
Please ensure the correct bus topology and its proper termination. For more
information see the CAN BUS section.
If the CAN bus speed is different than 1Mbps or if you want to isolate the ECU from the ADU CAN1
bus, please use the CAN2 bus.
Detailed information on connecting specific ECU brands to ADU can be found in the application
notes at www.ecumaster.com. Information about the channel configuration with CAN stream data
can be found in the CAN inputs section.