Operation Proline Prosonic Flow P 500 HART
154 Endress+Hauser
Parameter overview with brief description
Parameter Prerequisite Description User interface
Totalizer 1 to n value One of the following options is selected
in the Assign process variable
parameter (→  128) of the Totalizer
1 to n submenu:
Volume flow
Mass flow
Displays the current totalizer counter
value.
Signed floating-point
number
Totalizer 1 to n overflow One of the following options is selected
in the Assign process variable
parameter (→  128) of the Totalizer
1 to n submenu:
Volume flow
Mass flow
Displays the current totalizer overflow. Integer with sign
11.5 Adapting the measuring device to the process
conditions
The following are available for this purpose:
Basic settings using theSetup menu (→  94)
Advanced settings using theAdvanced setup submenu (→  125)
11.6 Performing a totalizer reset
The totalizers are reset in the Operation submenu:
Control Totalizer
Reset all totalizers
Navigation
"Operation" menu → Totalizer handling
Totalizer handling
Control Totalizer 1 to n
→  155
Preset value 1 to n
→  155
Totalizer value 1 to n
→  155
Reset all totalizers
→  155