Mounting Proline Prosonic Flow P 500 HART
42 Endress+Hauser
8. Insert the sensor cable into each individual sensor until the end stop and tighten the
locking nut.
A0043386
 40 Mounting the sensors and connecting the sensor cables
This completes the mounting procedure. The sensors can now be connected to
the transmitter via the sensor cables and the error message can be checked in the
sensor check function.
To ensure good acoustic contact, the visible measuring pipe surface must be clean
and free from flaking paint and/or rust.
If the sensor is removed from the measuring pipe, it must be cleaned and new
coupling gel applied (if there is no coupling pad).
On rough measuring pipe surfaces, the gaps in the rough surface must be filled with
sufficient amounts of coupling gel if use of the coupling pad does not suffice
(installation quality check).
6.2.5 Mounting the transmitter housing: Proline 500
L
CAUTION
Ambient temperature too high!
Danger of electronics overheating and housing deformation.
Do not exceed the permitted maximum ambient temperature →  27.
If operating outdoors: Avoid direct sunlight and exposure to weathering, particularly in
warm climatic regions.
L
CAUTION
Excessive force can damage the housing!
Avoid excessive mechanical stress.
The transmitter can be mounted in the following ways:
Post mounting
Wall mounting
Wall mounting
Required tools
Drill with drill bit ⌀ 6.0 mm