Operation Proline Prosonic Flow P 500 HART
144 Endress+Hauser
11 Operation
11.1 Reading off the device locking status
Device active write protection: Locking status parameter
Operation → Locking status
Function scope of the "Locking status" parameter
Options Description
None The access authorization displayed in the Access status parameter applies
→  74. Only appears on local display.
Hardware locked The DIP switch for hardware locking is activated on the PCB board. This locks write
access to the parameters (e.g. via local display or operating tool) →  142.
SIL locked The SIL mode is enabled. This locks write access to the parameters (e.g. via local
display or operating tool).
Temporarily locked Write access to the parameters is temporarily locked on account of internal
processes running in the device (e.g. data upload/download, reset, etc.). Once the
internal processing has been completed, the parameters can be changed once
again.
11.2 Adjusting the operating language
Detailed information:
To configure the operating language →  94
For information on the operating languages supported by the measuring device
→  209
11.3 Configuring the display
Detailed information:
On the basic settings for the local display →  120
On the advanced settings for the local display →  130
11.4 Reading off measured values
With the Measured values submenu, it is possible to read all the measured values.
Navigation
"Diagnostics" menu → Measured values
Measured values
Process variables
→  145
System values
→  149
Totalizer
→  153