Proline Prosonic Flow P 500 HART Diagnosis and troubleshooting
Endress+Hauser 179
12.10 Event logbook
12.10.1 Reading out the event logbook
A chronological overview of the event messages that have occurred is provided in the
Events list submenu.
Navigation path
Diagnostics menu → Event logbook submenu → Events list
F
I1091Config.change
I1157Mem.err.ev.list
F311Electr.failure
/../Eventlist
0d01h19m10s
A0014008-EN
72 Using the example of the local display
• A maximum of 20 event messages can be displayed in chronological order.
• If the Extended HistoROM application package (order option) is enabled in the device,
the event list can contain up to 100 entries.
The event history includes entries for:
• Diagnostic events → 172
• Information events → 180
In addition to the operating time when the event occurred, each event is also assigned a
symbol that indicates whether the event has occurred or is finished:
• Diagnostics event
• : Occurrence of the event
• : End of the event
• Information event
: Occurrence of the event
To call up the measures to rectify a diagnostic event:
• Via local display → 165
• Via web browser → 167
• Via "FieldCare" operating tool → 169
• Via "DeviceCare" operating tool → 169
For filtering the displayed event messages → 179
12.10.2 Filtering the event logbook
Using the Filter options parameter you can define which category of event message is
displayed in the Events list submenu.
Navigation path
Diagnostics → Event logbook → Filter options
Filter categories
• All
• Failure (F)
• Function check (C)
• Out of specification (S)
• Maintenance required (M)
• Information (I)