Proline Prosonic Flow W 400 HART Technical data
Endress+Hauser 157
Pulse/frequency/switch output
Pulse output
Fault mode Choose from:
• Actual value
• No pulses
Frequency output
Fault mode Choose from:
• Actual value
• 0 Hz
• Definable value between: 0 to 12 500 Hz
Switch output
Fault mode Choose from:
• Current status
• Open
• Closed
Local display
Plain text display With information on cause and remedial measures
Backlight Red lighting indicates a device error.
Status signal as per NAMUR recommendation NE 107
Interface/protocol
• Via digital communication:
HART protocol
• Via service interface
• CDI-RJ45 service interface
• WLAN interface
Plain text display With information on cause and remedial measures
Web browser
Plain text display With information on cause and remedial measures
Light emitting diodes (LED)
Status information Status indicated by various light emitting diodes
The following information is displayed depending on the device version:
• Supply voltage active
• Data transmission active
• Device alarm/error has occurred
Diagnostic information via light emitting diodes → 130
Low flow cut off The switch points for low flow cut off are user-selectable.