Operating menu
175
L00-FMU90xxx-19-08-02-en-106
R2103
relay 2
function:
limit xxxx
limit type:
standard
switch on point:
switch off point:
default: 60%
default: 40%
R2104
relay 2
switch delay:
invert.
yes
error handling:
hold
switch on
switch off
default: 0 s
no
actual value
A
R2103
relay 2
limit:
limit xxxx
limit type:
inband/out of bd.
upper switchpt.:
low switch point:
hysteresis
default: 60%
default: 40%
default: 1%
R2104
relay 2
switch delay:
invert:
yes
error handling:
hold
switch on
switch off
default: 0 s
no
actual value
B/C
R2103
relay 2
function:
limit xxxx
limit type:
tendency/speed
switch on /min:
switch off /min:
default: 60%
default: 40%
R2104
relay 2
switch delay:
invert:
yes
error handling:
hold
switch on
switch off
default: 0 s
no
actual value
R2103
relay 2
function:
time pulse
pulse width:
default: 200 ms
pulse time:
default: 1 min
R2104
relay 2
invert
yes
error handling:
stop
no
actual value
E
R2103
relay 2
function:
pulse flow 1
counter unit:
l
pulse value:
pulse width:
m3
default: 1.000 m3
default: 200 ms
R2105
relay 2
pulse counter:
overflow x 10^7:
reset counter
yes
start counter:
stop counter:
no
default: 0%
default: 100%
R2104
relay 2
invert:
yes
error handling:
hold
stop
no
actual value
R2104
relay 2
invert:
yes
no
G
R2103
relay 2
function:
diagnostics
allocation 1:
echoloss sen 1
allocation 2:
echoloss sen 2
none
none
R2104
relay 2
invert:
yes
no
R2104
relay 2
invert:
yes
no
I
R2104
relay 2
invert:
yes
no
J
D
F
H