Appendix
205
13.4 Default block configuration (HART)
13.4.1 Function blocks
The Prosonic S contains various function blocks. During the commissioning procedure the blocks
are linked to each other in order to perform the desired measuring task. Depending on the
instrument version and installation environment, the following function blocks may occur:
Signal inputs
•Sensor 1
Sensor 2 (if selected in the product structure)
Signal evaluation (calculation of the measured value)
Level 1
Level 2 (for instruments with 2 current outputs)
Flow 1 (for flow instruments)
Flow 2 (for flow instruments)
Controls
Pump control
Rake control
Backwater detection
Signal output
•Display
Current output 1 with HART
Current output 2 (if selected in the product structure)
•Relay 1
Relay 2 (for instruments with 3 or 6 relays)
Relay 3 (for instruments with 3 or 6 relays)
Relay 4 (for instruments with 6 relays)
Relay 5 (for instruments with 6 relays)
Relay 6 (for instruments with 6 relays)
13.4.2 Operating mode = "level"
1 sensor input / 1 current output
(FMU90 - *****1*1****)
L00-FMU90xxx-19-00-00-de-079
Sensor 1
Level 1
Current output 1
+HART
FDU9x
Display
Relay 1Alarm