13.1.6 Rectangular weirs
L00-FMU90xxx-05-00-00-xx-008
!
Note!
In the "width" parameter, the width of the weir can be adjusted. The corresponding change of the
flow curve is automatically performed by the Prosonic S.
!
Note!
After selecting the type of weir, Q
max
can be adjusted to the flow conditions. Q
max
defines the flow
at which the output current is 20 mA.
Type of weir B [mm] H
max
[mm] Q
max
[m
3
/h]
RectWT0/5H 1000 500 2418
RectWT0/T5 1000 1500 12567
kk
45°
BD
3H
max
2H
max
H
max
B
k3mm