The "level" menu
30
2.1.8 "LVL N check value" (N = 1 or 2)
L00-FMU90xxx-19-00-00-de-016
"actual distance N" (N = 1 or 2)
Displays the currently measured distance D
display
.
"check distance"
Use this parameter to state if the displayed distance D
display
matches the real distance D (measured
by a rule for example). Based on your selection, the Prosonic S automatically proposes a suitable
range of mapping.
You have got the following options:
distance = ok
Choose this option if the displayed value D
display
matches the real distance D.
After selecting this option, the Prosonic S changes to the "LVL N distance mapping" parameter
set. The preset range of mapping is identical to D. That means: all interference echos above the
current product surface will be suppressed by the mapping curve.
distance too small
Choose this option if the displayed value D
display
is smaller than the real distance D.
In this case the currently evaluated echo is an interference echo.
After selecting this option, the Prosonic S changes to the "LVL N distance mapping" parameter
set. The preset range of mapping is slightly larger than D
display
. Therefore, the currently evaluated
interference echo is suppressed by the mapping curve.
If after the mapping D
display
is still too small, repeat the mapping until D
display
matches the real
distance D.
distance too big
Choose this option if the displayed value D
display
exceeds the real distance D.
This error is not caused by interference echos. Therefore, no interference echo suppression is
performed and the Prosonic S returns to the "level 1(2)" submenu. Check the calibration
parameters, especially the "empty calibration" and the "application parameters".
distance unknown
Choose this option if you do not know the real distance D.
In this case, an interference echo suppression can not be performed and the Prosonic S returns to
the "level 1(2)" submenu.
manual
Choose this option if you want to define the range of mapping manually.
LVL1 check value L100B
act. distance 1:
check distance:
L100B
LVL1 dist. corr.
act. distance:D
D
display
D
display
=D
D
display
>D
D
display
<D
?