Appendix
188
13.1.5 Palmer-Bowlus flumes
L00-FMU90xxx-05-00-00-xx-007
!
Note!
After selecting the type of flume, Q
max
can be adjusted to the flow conditions. Q
max
defines the flow
at which the output current is 20 mA.
Type of flume D H
max
[mm] Q
max
[m
3
/h]
Palmer-Bowlus 6" 6" 120 38,08
Palmer-Bowlus 8" 8" 150 68,86
Palmer-Bowlus 10" 10" 210 150,2
Palmer-Bowlus 12" 12" 240 215,8
Palmer-Bowlus 15" 15" 300 377,6
Palmer-Bowlus 18" 18" 330 504,0
Palmer-Bowlus 21" 21" 420 875,6
Palmer-Bowlus 24" 24" 450 1077
Palmer-Bowlus 27" 27" 540 1639
Palmer-Bowlus 30" 30" 600 2133
D
D/4 D/4D/2
30°
30°
H
max
D/6
BD
H
D/2