Selecting and Starting a Test
96 88000 Series
Intelligent Apps
3b. From the Network block, either select the basic test parameters
or click on More for all settings (refer to Network Details (iSAM)
on page 269). The total bandwidth and the estimated test duration
are displayed.
3c. Select the remote operation mode; DTS is automatically selected
when the RFC 6349 Test is enabled:
3d. From the Remote block, either select the basic remote
parameters or click on More for all settings (refer to Remote
Details (iSAM) on page 287).
Note: The iSAM test application uses Internal timing for clock synchronization.
4. Tap the Start button from the right navigation bar to start the test (refer
to Start/Stop|TX Button on page 741). If the connection with the
remote module is not established with either DTS or Remote
Loopback mode, the automatic remote connection process is
performed before starting the test. The Summary result page will be
automatically displayed when the test is started from any Setup
configuration page. For additional results refer to Test Results on
page 385.
5. When the test ends automatically or is manually stopped, the generate
report pop-up is displayed by default. If required, tap Yes to generate a
report of the test results and statistics (refer to Report Button on
page 731 for more information).
DTS (Dual Test Set)
The remote device is automatically set in EtherSAM when the
connection/overtake is successfully established.
Remote Loopback
The remote device is automatically set in Smart Loopback when the
connection/overtake is successfully established.
Manual Loopback
The remote device is a physical loopback or has to be manually set in
loopback.