Test Setup - Test Configurator, Timer, and System
Power Blazer 181
eCPRI Flow - Profile
Measurement Rate, available with Sender measurement role,
defines the number of Latency/Jitter measurements to perform per
second: 1Measurements/s.
Frame Loss/Out-of-Sequence check box, when selected (default),
allows Frame Loss and Out-of-Sequence monitoring.
Remote
Status
Sender Receiver Description
Ready-R X X Indicates that one-way delay flows normally
between sender and receiver for both
request/response and remote request/request
Mismatch-R X - Indicates, for Sender measurement role, that
the remote end is also configured as Sender.
Inactive-R X X Indicates that there is no one-way delay
message received within 5 seconds that can be
caused by: a Link Down condition, an LOPPS-L
being present on the local or peer device, both
ends configured as Receiver, or incompatible
framing.
-- X X Indicates pending state which occurs upon
starting a test or when a Link Down condition
is detected.