EasyManua.ls Logo

EXFO Power Blazer - Page 340

EXFO Power Blazer
887 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test Setup - Test Configurator, Timer, and System
330 88000 Series
Signal
RX Termination
Power indicates the received signal level in dBdsx for DSn or dBm for
PDH and SONET/SDH.
Amplitude indicates the received signal amplitude as well as its MIN,
and MAX received values.
TX Frequency
Note: The following TX Frequency information applies to serial interface only,
refer to TX Frequency on page 214 for parallel interfaces.
TX Frequency (GHz) indicates the frequency (actual frequency +
Frequency offset) used for transmission.
Offset (ppm) check box, when selected (cleared by default), allows
setting the frequency offset that will be generated. Use the “+” or “-”
button to respectively increment or decrement the frequency offset
value based on the defined Increment/Decrement Size, or directly
type the frequency offset value in the field. Possible offsets are:
Signal Termination
DS1/E1 Ter m
a
, Mon, and Bridge.
a. Default value.
DS3/E3/E4/STS-1e/STM-0e/STS-3e/STM-1e Te r m
a
, and Mon
Interface Frequency Offset
a
Nominal Frequency
DS1 ±140 ppm 1544000 bit/s
E1 ± 70 ppm 2048000 bit/s