Test Results
Power Blazer 397
Alarms/Errors Overview
Mismatch ‘0’ (Available with EtherBERT and OTN BERT with EoOTN
client; not available with 100GE - 4Unframed CAUI-4 and OTU4 -
4 Unframed Physical Lanes on 88200NGE.)
RX: There is a bit error on a binary ‘0’ (for example ones that should be
zeros) found in the test pattern only.
Mismatch ‘1’ (Available with EtherBERT and OTN BERT with EoOTN
client; not available with 100GE - 4Unframed CAUI-4 and OTU4 -
4 Unframed Physical Lanes on 88200NGE.)
RX: There is a bit error on a binary ‘1’ (for example zeros that should be
ones) found in the test pattern only.
Clock
LOC (Loss Of Clock)
RX: The module is unable to synchronize with the selected Clock
Mode. No valid clock is generated/extracted to/from the EXT CLK port.
LOPPS-L and LOPPS-R (Loss Of Pulse Per Second - Local/Remote) are
only available in One-Way Latency measurement mode for Dual Test
Set and eCPRI BERT (LOPPS-L).
RX: Either no pulse is received or no pulse is received within 1 second
± 6.6 μs after the previous pulse. LOPPS-R is only monitored once the
DTS connection is established.