Test Results
398 88000 Series
Alarms/Errors Overview
CPRI
Note: CPRI alarms/errors are only available for Framed L2.
Alarms
Link Down
RX: Indicates that the start-up sequence is not in F (Operation) or G
(Passive) link state.
LOF (Loss Of Frame)
RX: The hyperframe alignment cannot be achieved or is lost.
R-LOS (Remote - Loss Of Signal)
RX: Bit 3 of the Z.130.0 byte is set to 1.
R-LOF (Remote - Loss Of Frame)
RX: Bit 4 of the Z.130.0 byte is set to 1.
RAI (Remote Alarm Indication)
RX: Bit 1 of the Z.130.0 byte is set to 1.
SDI (Service Access Point Defect Indication)
RX: Bit 2 of the Z.130.0 byte is set to 1.
Errors
FAS (Frame Alignment Signal)
RX:
For rates up to 9.8G, error detected in the start of hyperframe (byte
different of K28.5 while not in LOF).
For rate 10.1G, error detected in the sync control word of hyperframe
(byte different of /S/ while not in LOF).