Test Results
426 88000 Series
Alarms/Errors Overview
For parallel interfaces:
For serial interfaces:
Rate Optic Type Frequency
40GE 4x10G 10.3125 Gbit/s ± 100 ppm
OTU3 4x10G 10.7546 Gbit/s ± 20 ppm
OTU3e1 4x10G 11.1427 Gbit/s ± 20 ppm
OTU3e2 4x10G 11.1458 Gbit/s ± 20 ppm
100GE 4x25G 25.78125 Gbit/s ± 100 ppm
100G FlexO-1-RS 4x28G 27.952 Gbit/s ± 20 ppm
200GE 4x50G 26.5625 Gbit/s ± 100 ppm
400GE 8x50G 26.5625 Gbit/s ± 100 ppm
OTU4 4x25G 27.952 Gbit/s ± 20 ppm
Interface Standard Rate Specification
DS1 1544000 ±36.6 ppm
E1 2048000 ±54.6 ppm
E3 34368000 ±24.6 ppm
DS3 44736000 ±24.6 ppm
STS-1e/STM-0e, OC-1/STM-0 51840000 ±20 ppm
E4 139264000 ±19.6 ppm
STS-3e/STM-1e, OC-3/STM-1 155520000 ±20 ppm
OC-12/STM-4 622080000 ±20 ppm
OC-48/STM-16 2488320000 ±20 ppm
OTU1 2666057143 ±20 ppm
OC-192/STM-64 9953280000 ±20 ppm
OTU2 10709225316 ±20 ppm
OTU1e 11049107143 ±100 ppm
OTU2e 11095727848 ±100 ppm
OTU1f 11270089286 ±100 ppm
OTU2f 11317642405 ±100 ppm