Technical data 97
DC voltage based derating
The available output power of the inverter depends on both the input DC voltage and the
ambient temperature. The illustration shows this relation (for elevations below 1000 m).
The behavior of the inverter corresponds to the actual PV panel behavior at high
temperatures and ensures optimal performance of the whole PV plant.
The minimum operational DC voltage varies based on the inverter AC voltage:
PVS980-58-1818kVA-I: 850 V DC
PVS980-58-1909kVA-J: 893 V DC
PVS980-58-2000kVA-K: 935 V DC
PVS980-58-2091kVA-L: 978 V DC
101.5%
U
DC
(V
DC
)
U
DC,min
S
o,max
/S
o,nom
1500
0
130012001000
1100
1150
1050
110.0%
89.0%
100.0%
55
o
C
80.0%
71.5%
50
o
C
1350
чϮϱ
Ϯϱфdчϯϱ
Ϯϱфdчϯϱ
1250
Outputpowervs.DCvoltage,ĞůĞǀĂƟŽŶчϭ000ŵ