Common Causes of Twisted Pair Test
Failures
Table 4-1 describes common causes of test failures on
twisted pair cabling.
Table 4-1. Diagnosing Twisted Pair Test Failures
Wire Map: open
Wires connected to wrong pins at connector or punchdown blocks
Faulty connections
Damaged connector
Damaged cable
Wrong Outlet Configuration selected in setup
Wrong application for cable
Wire Map: split pair or reversed pair
Wires connected to wrong pins at connector or punchdown block.
-continued-