Step 4: Viewing the Autotest Results
The Summary screen, shown in Figure 2-6, tells you if the
test results met the selected test limit. This screen also
shows a status for each measurement:
E: PASS
F: FAIL
i: The results are for informational purposes only.
The measurement is not required by the selected
test limit.
7: The measurement is within the tester’s accuracy
uncertainty range. See Chapter 3 for details.
To see the results for an individual measurement, use
D to highlight the test; then press H.
If the test failed, press
J Fault Info. for a diagnosis of
the fault. Figure 2-6 shows a typical diagnostic screen.
The Next Fault softkey is available if the tester detected
more than one fault. See Chapter 4 for more information
on diagnosing faults.
See Chapter 3 for details on twisted pair test results.
Autotest Summary
Screen
Diagnostic
Screen
amd119f.eps
Figure 2-6. Autotest Summary and Diagnostic Screens