EasyManua.ls Logo

Fluke DTX Series - Step 3: Selecting a Fiber Type and Test Limit

Fluke DTX Series
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tutorials on Setup and Test Procedure
Certifying Fiber Cabling 2
2-15
TALK
MONITOR
ENTER
TEST
SAVE
SPECIAL
FUNCTIONS
SETUP
AUTO
TEST
SINGLE
TEST
EXIT
F1 F2 F3
TALK
TEST
PASS
TEST
FAIL
TALK
TONE
SC to SC patch cords
amd118f.eps
Figure 2-9. Self Test Connections for Fiber Modules
Step 3: Selecting a Fiber Type and Test Limit
Select the cable type and test limit specified for the job.
3-1 Turn the rotary switch to SETUP.
3-2 Use
D to highlight Fiber; then press H.
3-3 On the Fiber menu press H to select Fiber Type.
Fiber types are organized in groups:
Generic: Generic types of fiber
Manufacturer: Specific brands of fiber cable
3-4 Use
D to highlight a group for the fiber type
you will test; then press
H.
3-5 Use
D to highlight the fiber type you will test;
then press
H.
3-6 On the Fiber menu, use
D to highlight Test
Limit; then press
H.
3-7 The first Test Limit screen shows the most recently-
used limits. To see the list of test limit groups, press
JMore.
3-8 Use
D and H to select a different limit
group, if necessary, and to select the test limit
required for the job.