Diagnosing Twisted Pair Cabling Faults
The HDTDX Analyzer 4
4-11
Recognizing Faults on HDTDX Plots
Figure 4-2 shows how some common faults appear on
HDTDX plots.
1
Bad connector
2
Bad section of cable
3
Bad spool of cable
amd98f.eps
A A bad connector at the end of a patch cord near the
main tester.
B Bad section of cable near the smart remote.
C A spool of cable with poor NEXT performance. This
cable produced a FAIL result. Note the crosstalk along
the entire length of the cable.
Figure 4-2. Interpreting HDTDX Plots