DTX Series CableAnalyzer
Technical Reference Handbook
9-16
Time for Autotest
Full 2-way Autotest of Category 6 UTP cable in 12
seconds or less.
Summary of Performance Specifications
Note
All specifications for tests on twisted pair
cabling apply to 100
Ω
cable. Contact Fluke
Networks for information on measurement
performance for cable with a different
impedance.
For Category 6/Class E test modes or below, the DTX
CableAnalyzer is compliant with Level III requirements of
TIA/EIA-568-B.2-1 and IEC 61935-1.
For Class F test modes, the DTX-1800 is compliant with
Level IV requirements as in the draft 2
nd
edition of IEC
61935-1.
Length
Note
Length specifications do not include the
uncertainty of the cable’s NVP value.
Twisted Pair Cabling
Parameter
Single-ended
Test
Dual-ended Test
(main and remote)
Range 800 m (2600 ft) 150 m (490 ft)
Resolution 0.1 m or 1 ft 0.1 m or 1 ft
Accuracy ± (1 m + 4 %) ± (1 m + 4 %)