Tutorials on Setup and Test Procedure
Certifying Fiber Cabling 2
2-19
Step 7: Viewing the Results
The Summary screen, shown in Figure 2-12, tells you if the
test results met the selected test limit. This screen also
shows a status for each measurement:
E: PASS
F: FAIL
i: The results are for informational purposes only.
The measurement is not required by the selected
test limit.
To see the results for an individual measurement, use
D to highlight the test; then press H.
See Chapter 5 for details on fiber test results.
amd121f.eps
Figure 2-12. Summary Results Screen for an Autotest
on Fiber