Tutorials on Setup and Test Procedure
Certifying Twisted Pair Cabling 2
2-7
Step 1: Checking the Battery Status and Verifying
Operation with Twisted Pair Adapters
You should check the tester and smart remote’s battery
status and verify all equipment is in good working order
before going to the job site.
1-1 Connect the tester and smart remote together as
shown in Figure 2-3.
1-2 Turn the rotary switch to SPECIAL FUNCTIONS.
1-3 Use
D to highlight Battery Status; then press
H. Press I when you are done.
1-4 Use
D to highlight Self Test; then press H.
1-5 Press Pto start the self test.
Note
You can also check the battery status by
connecting channel adapters with a patch cord,
or by connecting the tester and smart remote
through a link.
P