Maintenance and Specifications
Specifications 9
9-33
CSA Standards
CAN/CSA-C22.2 No. 1010.1-92 + Amendment 2: 1997 and
CAN/CSA-C22.2 No. 1010.1 2000 (2
nd
edition) Safety
Requirements for Electrical Equipment for Measurement,
Control, and Laboratory Use, Part 1: General
Requirements.
Safety
CAN/CSA-C22.2 No. 1010.1-92 + Amendment 2: 1997;
Overvoltage Category II, Pollution degree 2, 30 V.
EN61010, 2nd Edition, MEASUREMENT (Installation)
CATEGORY I, Pollution Degree 2 per IEC1010-1 refers to
the level of Impulse Withstand Voltage protection
provided. Equipment of MEASUREMENT CATEGORY I is
for measurements performed on circuits not directly
connected to mains.
Laser Classification and Safety for DTX-MFM and
DTX-SFM Fiber Modules
OUTPUT port: Class 1
VFL port: Class 2
Complies with EN60825-1 and EN61010-1 (CE) and CFR21
Memory for Test Results
Internal memory stores up to 250 Cat 6 Autotest results,
including graphical data.
The 16 MB memory card included stores up to 500 Cat 6
Autotest results, including graphical data.
1 MB Flash EPROM allows software and test limit updates.
LinkWare software lets you upload Autotest results to a
PC from the tester or a memory card reader.