DTX Series CableAnalyzer
Technical Reference Handbook
4-10
1
2
4
5
6
3
amd19f.eps
A The magnitude of crosstalk on the cable pairs. Crosstalk levels shown
on the plot are adjusted to compensate for insertion loss. This means
that the levels represent the magnitudes of the signals as they
appear at the crosstalk source.
To see the crosstalk on just one pair, press
L Plot By Pair. Press I
to return to the plot of all pairs.
B Magnification level for the plot. Use AD to zoom in or
out at the cursor’s location.
C The beginning and end of the cabling under test. The plot shows
0.7 m before and after the beginning and end for a permanent link.
D The distance to the end of the cabling.
E The cursor and the distance to the cursor from the tester. Use BC to
move the cursor.
F Readouts showing the distance between the measurement cursors.
To use the measurement cursors:
1 Use
BC to move the cursor to the beginning of an area of
interest. Use
AD to zoom in on the area if desired.
2 Press
J Set Marker; then use BCto move the second cursor
to the end of the area of interest.
Figure 4-1. HDTDX Plot