Table 4-1. Diagnosing Twisted Pair Test Failures (cont.)
Propagation delay or delay skew gives FAIL result
Cable is too long (may need to remove coiled service loops)
Cable uses different insulation materials on different pairs
Impulse noise is detected
Electrical devices near the cabling are generating noise pulses.
There is an active link in the same bundle as the cabling under test.
Verify that the tester and smart remote are operating correctly. Connect the units together and run an Autotest.