Certifying Fiber Optic Cabling
Autotest in Far End Source Mode 5
5-33
11 To enter patch cord lengths to meet TSB-140
reporting requirements, press
J Patch Lengths.
On the Patch Lengths screen, enter the lengths of
the patch cords used for reference and test
connections.
Press
N when you are done.
Caution
Do not disconnect the patch cord from the
smart remote’s output after setting the
reference. If you do, you must set the reference
again to ensure valid measurements.
Adapter
INPUT
port
Patch cords that match the fiber and
connectors to be tested with SC
at tester end
TALK
MONITOR
ENTER
TEST
SAVE
SPECIAL
FUNCTIONS
SETUP
AUTO
TEST
SINGLE
TEST
EXIT
F1 F2 F3
Tester
Mandrel used only for
multimode fiber.
*
Smart remote
Mandrel*
OUTPUT
port
TEST
LOW BATTERY
TONE
TAL K
FAI L
TEST
PASS
TALK
Button activates
output. See page 5-32.
amd125f.eps
Figure 5-15. Far End Source Mode Reference Connections (Modified Method B)