DTX Series CableAnalyzer
Technical Reference Handbook
5-42
To use the FindFiber function in Smart Remote mode:
1 Turn the rotary switch to SETUP; then select Fiber.
2 Select Remote End Setup; then select Smart Remote.
3 Clean all connectors; then make the connections
shown in Figure 5-21.
4 Turn the rotary switch to MONITOR; then select
FindFiber.
5 Try various connections to the patch panel with the
main tester’s INPUT fiber until the input fiber’s status
shows Connected.
6 Then try various connections with the main tester’s
OUTPUT fiber until the output fiber’s status shows
Connected.
Figure 5-20 shows the main tester results for Smart
Remote mode.
amd103f.eps
amd104f.eps
amd105f.eps
The main tester’s INPUT fiber path is
not complete. The main tester cannot
determine the state of the OUTPUT
fiber path.
The main tester’s INPUT fiber path is
complete. The main tester’s OUTPUT
fiber path is not complete.
Both fiber paths are complete.
Figure 5-20. Main Tester Results for FindFiber Test (Smart Remote Mode)