Certifying Twisted Pair Cabling
Twisted Pair Test Settings 3
3-5
Table 3-1. Twisted Pair Test Settings (cont.)
Setting Description
SETUP > Instrument
Settings > Store Plot
Data
Yes: the tester displays and saves plot data for frequency-based tests such as NEXT, return loss,
and insertion loss. This lets you include plots on test reports created in LinkWare software.
No: plot data is not displayed or saved, which lets you save more results.
SPECIAL FUNCTIONS >
Set Reference
The tester must be referenced to the smart remote the first time the two units are used
together. You should also set the reference every 30 days. See “Setting the Reference” on page
3-1.
SETUP > Instrument
Settings
Settings for saving tests
Cable ID Source, Current Folder, Result Storage Location (DTX-1800, DTX-1200), Operator, Site,
and Company. See “Preparing to Save Tests” in Chapter 2.