DTX Series CableAnalyzer
Technical Reference Handbook
3-10
Figure 3-5 describes the Autotest Summary screen.
A PASS: All parameters are within limits.
FAIL: One or more parameters exceeds the limit.
PASS*/FAIL*: One or more parameters are within the tester’s accuracy
uncertainty range, and the “*” notation is required by the selected
test standard. See “PASS*/FAIL* Results” on page 3-12
B Press K or L to scroll the screen.
C If the test failed, press J for diagnostic information.
D Action prompt for the screen. Use D A to highlight a
parameter; then press
H.
1
2
3
4
5
amd77f.eps
E E: The measurement was within limits.
i: The parameter was measured, but has no PASS/FAIL limit in the
selected test limit. The results are for informational purposes only.
X: The measurement exceeds the limit.
U: See “PASS*/FAIL* Results” on page 3-12.
Figure 3-5. Autotest Summary Screen for Twisted Pair Cabling

Table of Contents