Managing hardware Managing units of the SE server
U41855-J-Z125-3-76 251
Dokuschablonen 19x24 Version 7.4de für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
19. March 2018 Stand 18:42.31 Pfad: P:\FTS-BS\Server\SE-Server\SE-Doku\1303912_BuV_062\BuV_e\buv.k10
Ê If the AU is connected via MANPU or MONPR01 IPv4, select No and enter the IP
address.
Changing access data of the Application Unit
You can change the access data of the Application Unit only if the Application Unit is
operated with the VMware vSphere, Microsoft HyperV oder Citrix XenServer operating
system.
Ê In the Access data group, click the Change AU password icon for the required account,
change the account / password in the subsequent dialog box, and confirm the action.
Changing access data of the Application Unit's iRMC access
The hardware status is determined for all Application Units using the iRMC. When the
password on the iRMC is changed, you must also change the password here.
Ê In the iRMC Access data group, click the Change IP address and password icon by the
required IP address iRMC, change the IP address iRMC or the Password and confirm the
action.
i semuser is permanently assigned as account. An account with this name must be
created in the iRMC of the AU. The account must have the LANchannel privilege
Administrator, SerialChannel Privilege user rights.
Also see "Status monitoring via the iRMC of the Application Unit" in the appendix of
the online help.
Managing IP configuration of an Application Unit PQ
IP configuration of an AU PQ is distributed to the Chassis and Partition levels.
At chassis level, access to the Management Board is configured centrally:
Ê Select Hardware → Units[ → <se server> (SE<model>)] → <unit> (<AU PQ model>) →
Management, IP configuration tab.
In the Management Board access data area you can change the IP address and password.
i The account semuser is permanently assigned. The account must be configured
in the web UI of the Management Board and have the admin privilege for the
Remote Server Management.
At partition level access to the particular partition's system is configured:
Ê Select Hardware → Units[ → <se server> (SE<model>)] → <unit> (<AU PQ model>) →
<partition> → Management, IP configuration tab.
In the IP network area you can update network data analogously to AU PY (see
“Updating network data” on page 250).