Architecture and strategies Management Unit and SE Manager
U41855-J-Z125-3-76 53
Dokuschablonen 19x24 Version 7.4de für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
19. March 2018 Stand 18:25.47 Pfad: P:\FTS-BS\Server\SE-Server\SE-Doku\1303912_BuV_062\BuV_e\buv.k02
2.6.4 Central logging
The SE server configuration provides centralized access to the "Audit" and "Event Logging"
functions as well as to the alarm management.
Audit logging logs every action that is executed on a Unit (MU, SU, HNC) of the SE server
configuration via the SE Manager, an add-on or a CLI command. Thus, every administrator
can always see who performed which action with which result and when.
The SE Manager displays all occurring events in the event logging with a timestamp,
weight, name of the reporting unit, name of the reporting component and message text. The
most recent events are displayed first. To provide a better overview, the recent events that
you have not yet seen are also displayed in the Current events tab. The Dashboard displays
a summary of this overview in a separate tile.
The SE Manager displays the audit and event logging entries in the Logging → Audit logging
and Logging → Event logging menu (see “Displaying audit logging” on page 323 and
“Displaying event logging” on page 325).
With the alarm management you can configure automatic SNMP trap or e-mail messages
for events with certain weights; this enables you to recognize important events like error
situations earlier and to react quickly if necessary, even in large SE server configurations.
The SE Manager displays the alarm management configuration in the Logging → Alarm
management menu (see “Alarm management” on page 327).