Managing hardware Managing energy settings
U41855-J-Z125-3-76 293
Dokuschablonen 19x24 Version 7.4de für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
19. March 2018 Stand 18:42.31 Pfad: P:\FTS-BS\Server\SE-Server\SE-Doku\1303912_BuV_062\BuV_e\buv.k10
Three areas are displayed:
1. You can change the settings for the template in the Energy Templates Units group.
2. The Summary group contains a summary of the total consumption of all units and the
maximum energy saving with the saving options simulated in the template
implemented.
3. The Saving group displays the maximum total saving with respect to the total
consumption in the form of a red bar. The saving, the total consumption and the newly
calculated consumption (total consumption - maximum saving) are also displayed.
10.6.3 Scheduled power on/off of units of the SE server
Ê Select Hardware → Energy [→ <se server>(SE<model>)], Scheduled power on/off tab.
A list is displayed containing all the units of the SE server which can be powered on and off
on a scheduled basis.
The power on/off times currently set and the current power status are displayed for each
unit of the type MU, HNC, SU, and AU. You can define, change, and reset new power on/off
times for each day of the week.
i The functionality is not supported for SU /390 and AU PQ.