Managing hardware Managing IP networks
U41855-J-Z125-3-76 267
Dokuschablonen 19x24 Version 7.4de für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
19. March 2018 Stand 18:42.31 Pfad: P:\FTS-BS\Server\SE-Server\SE-Doku\1303912_BuV_062\BuV_e\buv.k10
10.2.3.1 Add network
Ê Select Hardware IP networks Data Network Private Overview tab. The Overview
tab with all information on the existing DANPRs opens.
Ê Click Add network.
The Add network dialog box opens and the first free network name is reserved.
Ê Follow the instructions of the wizard and enter the network data. Detailed information is
provided in the SE Manager help.
i In the wizard, the available ports of the units (MU, SU x86, HNC) are only offered in
the selection list in dependence to the selected mode (tagged, untagged or dual).
The ports of the MUs are only offered for selection in the tagged mode. If another
mode was selected, the ports of the MUs can be added afterwards at the respective
DANPR<nn> via Add ports (see “Overview of the various DANPRs” on page 266).
10.2.3.2 Activate RADVD / DNS / NTP server
You can activate the RADVD / DNS / NTP server in the local MU for each DANPR:
Ê Select Hardware IP networks Data Network Private DANPR<no>, Overview tab.
Ê Click Activate RADVD / DNS / NTP server.
Ê The Activate RADVD / DNS / NTP server dialog box opens. Click Activate.
i In an SE server configuration with multiple MUs, this action is only available for the
local MU (the MU on which you are logged in). To activate another MU, you have to
switch to the SE Manager of that MU. In case of a global session: Switching is
possible via the link in the header of the SE Manager.
For reasons of redundancy we recommend to activate the RADVD / DNS / NTP
server on all MUs of the SE server configuration.
Note:
At least one port of the respective MU must be assigned to the network.
The IP address column for already entered MUs displays the IPv6 address of the MU
in the network. If you drag the mouse over the i icon, a tool tip informs you whether
the entry is the local MU or a remote MU.

Table of Contents

Other manuals for Fujitsu BS2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu BS2000 and is the answer not in the manual?

Fujitsu BS2000 Specifications

General IconGeneral
BrandFujitsu
ModelBS2000
CategoryServer
LanguageEnglish

Related product manuals