Concord 4
Installation Manual
90
Fire shutdown (09002)
Default setting is Off.
This setting determines whether system sirens turn off during a fire alarm audio session. To turn the setting off
or on, do the following:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows FIRE
SHUTDOWN OFF/ON (current setting).
2. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display shows the new
setting.
Silent talkback (09003)
Default setting is Off.
This setting determines whether the central station operator can speak to persons on the premises (on) or only
listen (off) during a silent or duress alarm audio session. To turn the setting off or on, do the following:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows SILENT
TALKBACK OFF/ON (current setting).
2. Press 1 (off) or 2 (on). The display flashes the entered setting. Press # and the display shows the new
setting.
Access timeout (09004)
Default setting is 90 seconds.
If the Audio mode is set to Instant, then this setting determines how much time (30 to 300 seconds, in 2-second
increments) the central station operator has to enter the AVM access code after the panel is accessed for an
audio session.
To change the Access timeout, do the following:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows ACCESS
TIMEOUT nn SECS (current setting).
2. Enter the desired time. The display flashes the entered setting. Press # and the display shows the new
setting.
Beep delay (09005)
Default setting is 2 seconds.
This setting determines how long AVM access beeps are delayed (0 to 300 seconds, in 2-second intervals) at
the beginning of a 2-way audio session.
To change the Beep delay, do the following:
1. With the display showing AUDIO VERIFY OFF/ON, press A or B until the display shows BEEP
DELAY nn SECS (current setting).
2. Enter the desired time. The display flashes the entered setting. Press # and the display shows the new
setting.