To assign a keyswitch sensor, do the following:
1. With the display showing KEYSWITCH SENSOR nn (current sensor number), enter the desired
sensor number (01–96).
2. The display flashes the entered sensor number. Press # and the display shows the new number.
To delete a keyswitch sensor, with the display showing KEYSWITCH SENSOR nn (current sensor number),
press D to erase the keyswitch sensor attribute.
Keyswitch style (0015 to 0065)
Default setting is Transition.
This feature determines how the system behaves when armed/disarmed by a keyswitch sensor. The choices are
as follows:
Transition. If keyswitch style is set to transition and the keyswitch sensor is tripped (opened) when the
system is disarmed, the panel will automatically arm to Away. If the sensor is tripped (opened) when the
system is armed to Away or Stay, the panel will automatically disarm
State. If keyswitch style is set to state, when the keyswitch sensor is tripped (opened) the panel arms to
Away. If the sensor is restored (closed) the panel disarms.
Opening, closing, and force arming reports (if turned on) are reported to the central station for both keyswitch
styles.
To assign a keyswitch style, do the following:
1. With the display showing KEYSWITCH STYLE TRANSITION/STATE (current setting), press 1 for
Transition or 2 for State.
2. The display flashes the entered setting. Press # and the display shows the new setting.
Duress code (0016 to 0066)
Default setting is Transition.
The duress code is a unique 4-digit access code that allows users to operate the system and, at the same time,
instructs the panel to send a silent alarm report to the central station.
Do not use a duress code unless it is absolutely necessary. Using duress codes often results in false alarms due
to code entry errors.
Note: To use this feature, the Duress option setting under the Reporting menu on page 73 must be turned on.
To program a duress code, do the following:
1. With the display showing DURESS CODE ****, enter the desired 4-digit duress code.
2. The display flashes the entered setting. Press # and the display shows the new code.
To delete a duress code, do the following:
1. With the display showing DURESS CODE nnnn (current code), press D.
2. The display shows DURESS CODE ****.